Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1973 1
1981 1
1983 3
1984 3
1985 2
1987 3
1988 1
1989 2
1991 1
1992 1
1993 1
1994 3
1996 2
1997 1
2004 2
2005 1
2006 2
2007 1
2008 2
2009 2
2010 1
2011 1
2015 1
2016 1
2019 1
2020 1
2021 3
2022 1
2023 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

43 results

Results by year

Filters applied: . Clear all
Page 1
Filter Fluorometer Calibration Without the Fluorometer.
English CM, Kitzhaber ZB, Sanim KRI, Vitzilaios N, Hodgson ME, Richardson TL, Myrick ML. English CM, et al. Appl Spectrosc. 2023 Sep;77(9):1053-1063. doi: 10.1177/00037028231181593. Epub 2023 Jun 23. Appl Spectrosc. 2023. PMID: 37350765
We recently described a lightweight, low-power, waterproof filter fluorometer using a 180 backscatter geometry for chlorophyll-a (chl-a) detection. ...
We recently described a lightweight, low-power, waterproof filter fluorometer using a 180 backscatter geometry for chlorophyll-a (chl …
Using fluorophore-labeled oligonucleotides to measure affinities of protein-DNA interactions.
Anderson BJ, Larkin C, Guja K, Schildbach JF. Anderson BJ, et al. Methods Enzymol. 2008;450:253-72. doi: 10.1016/S0076-6879(08)03412-5. Methods Enzymol. 2008. PMID: 19152864 Free PMC article. Review.
Topics include selection of a fluorophore, experimental design using a fluorometer equipped with an automatic titrating unit, and analysis of direct binding and competition assays....
Topics include selection of a fluorophore, experimental design using a fluorometer equipped with an automatic titrating unit, and ana …
Frequency domain fluorometry with pulsed light-emitting diodes.
Herman P, Vecer J. Herman P, et al. Ann N Y Acad Sci. 2008;1130:56-61. doi: 10.1196/annals.1430.026. Ann N Y Acad Sci. 2008. PMID: 18596332 Review.
We present a simple way to extend the time resolution of a standard frequency domain (FD) fluorometer by use of pulsed light-emitting diodes (LEDs) as an excitation source. ...By a replacement of the light source, the upper frequency limit increased to 500-600 MHz, which i …
We present a simple way to extend the time resolution of a standard frequency domain (FD) fluorometer by use of pulsed light-emitting …
A modern, simple, and economical accessory for continuous L-format measurement of steady-state fluorescence anisotropy.
Rendon DA, Palacio JL. Rendon DA, et al. Anal Biochem. 2022 Feb 15;639:114473. doi: 10.1016/j.ab.2021.114473. Epub 2021 Nov 16. Anal Biochem. 2022. PMID: 34798122
In this study, the pros and cons of the most relevant L-format devices reported in the literature for measuring steady-state fluorescence polarization/anisotropy are identified. Combining all this information, and with the use of modern elements for the acquisition, treatm …
In this study, the pros and cons of the most relevant L-format devices reported in the literature for measuring steady-state fluorescence …
Computer vision vs. spectrofluorometer-assisted detection of common nitro-explosive components with bola-type PAH-based chemosensors.
Kovalev IS, Sadieva LK, Taniya OS, Yurk VM, Minin AS, Santra S, Zyryanov GV, Charushin VN, Chupakhin ON, Tsurkan MV. Kovalev IS, et al. RSC Adv. 2021 Jul 27;11(42):25850-25857. doi: 10.1039/d1ra03108b. eCollection 2021 Jul 27. RSC Adv. 2021. PMID: 35479431 Free PMC article.
The PAH components of these chemical bolas are able to form stable, bright emissive in a visual wavelength region excimers, which allows their use as extended matrices of the RGB colors after imaging and digital processing. In non-polar solvents, the excimers have poor che …
The PAH components of these chemical bolas are able to form stable, bright emissive in a visual wavelength region excimers, which allows the …
Construction and performance of a variable-frequency phase-modulation fluorometer.
Lakowicz JR, Maliwal BP. Lakowicz JR, et al. Biophys Chem. 1985 Jan;21(1):61-78. doi: 10.1016/0301-4622(85)85007-9. Biophys Chem. 1985. PMID: 3971026
We describe the construction and performance of a variable-frequency phase-modulation fluorometer. This instrument, which provides modulation frequencies from 1 to 200 MHz, was constructed using commercially available components. ...We also resolved an especially difficult …
We describe the construction and performance of a variable-frequency phase-modulation fluorometer. This instrument, which provides mo …
Development of fluorescence change-based, reagent-less optic immunosensor.
Aoyagi S, Kudo M. Aoyagi S, et al. Biosens Bioelectron. 2005 Feb 15;20(8):1680-4. doi: 10.1016/j.bios.2004.06.041. Biosens Bioelectron. 2005. PMID: 15626628
After stabilization of the fluorescence intensity, IgG was added and the time-course of the fluorescence intensity was measured on a fluorometer connected with the optic fibers. Furthermore, the fluorescence response of a transient state was evaluated with the same system. …
After stabilization of the fluorescence intensity, IgG was added and the time-course of the fluorescence intensity was measured on a fluo
Automated fluorescence polarization immunoassay for monitoring vancomycin.
Schwenzer KS, Wang CH, Anhalt JP. Schwenzer KS, et al. Ther Drug Monit. 1983;5(3):341-5. doi: 10.1097/00007691-198309000-00017. Ther Drug Monit. 1983. PMID: 6636261
We have extended fluorescence polarization immunoassay (FPIA) technology for the measurement of drugs to include the complex amphoteric glycopeptide antibiotic vancomycin (molecular weight, 1,449). ...Tracer, sample, and diluted antiserum were combined, and the polariza
We have extended fluorescence polarization immunoassay (FPIA) technology for the measurement of drugs to include the complex amphoter …
Development of a rapid polarized total synchronous fluorescence spectroscopy (pTSFS) method for protein quantification in a model bioreactor broth.
Boateng BO, Elcoroaristizabal S, Ryder AG. Boateng BO, et al. Biotechnol Bioeng. 2021 May;118(5):1805-1817. doi: 10.1002/bit.27694. Epub 2021 Feb 4. Biotechnol Bioeng. 2021. PMID: 33501639
Here we present the early-stage development and optimization of a polarized total synchronous fluorescence spectroscopy (pTSFS) method for protein quantification in a hydrolysate-protein model (mimics clarified bioreactor broth samples) using a standard benchtop laboratory …
Here we present the early-stage development and optimization of a polarized total synchronous fluorescence spectroscopy (pTSFS) metho …
Dynamics of membrane structure of frog erythrocyte ghosts measured with a nanosecond fluorometer.
Koyama T, Araiso T, Nitta J. Koyama T, et al. Biorheology. 1987;24(3):311-7. doi: 10.3233/bir-1987-24304. Biorheology. 1987. PMID: 3663892
The dynamics of membrane microstructure was studied as molecular motions of phospholipids for bullfrog erythrocyte ghosts by the DPH fluorescence depolarization technique with a nanosecond fluorometer. The bullfrog erythrocyte ghosts were obtained by hypotonic lysis and co …
The dynamics of membrane microstructure was studied as molecular motions of phospholipids for bullfrog erythrocyte ghosts by the DPH fluores …
43 results